News Headlines

Sat. Aug 21st 2010
Standby for the Schulykill County Convention

Today the engine, tower, squad and ambulance headed up to Frackville to standby for the convention. Due to the regular first ...

Read more »


Sat. Jun 12th 2010
Engine and Ambulance attend Dauphin County Fireman's Convention

Today the engine and the ambulance made the trip to Wiconisco for the Dauphin County Convention. Despite the temperatures the...

Read more »


Fri. Jun 4th 2010
Pictures Of The Past

We have decided to upload some old time photos of the past Historic Fires and Company events for all to enjoy.

Read more »

Apparatus Gallery
Newsletter Subscription

Stay up to date!
Subscribe to our Newsletter.


Enter Your Email Address:



Contact Information

Citizens Fire Company #2
212 W. Centre St.
Mahanoy City, PA  17948

Non-Emergency:
570-773-1750

Emergency:
911

Fax:
570-773-0502

Contact Us
Driving Directions
Map

Member Login

Username:


Password:




Links

Vent Enter Search


Your First Due

Fire Company Web Sites


Gibraltar Fire Co.




 Fire Glossary
 Print this page

Search:

Click a letter to view all entries that begin with that letter:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Page: | 1 |

IAFF
Acronym, International Association Of Fire Fighters".


IDLH
Any situation deemed Immediately Dangerous to Life and Health. More narrowly defined by OSHA. See main IDLH article. An area of maximum danger to firefighters.


IFSTA
Acronym, International Fire Service Training Association". A major publisher of firefighter training materials.


Incident Command System (ICS)
System first developed to provide a command structure to manage large wildfires in the United States, now widely used by many emergency management agencies.


Incident Commander
The officer in charge of all activities at an incident. See Incident Command System.


Incident Safety Officer
The officer in charge of scene safety at an incident. See Incident Command System.


Indian pump
(aka Indian Tank) A brand of five-gallon water can, or back-pack bladder, featuring a short hose and hand pump for use in wildland firefighting.


Indian pump
Water vessel carried on one's back, either a rigid can or collapsible bag, with a hose and telescoping squirt pump. Contains 5 US gal, and is used on hot spots and during mop up. Also called bladder bag (if collapsible), piss pump, or Fedco.


Indirect attack
A method of suppression in which the control line is located some considerable distance away from the fire's active edge. Generally done in the case of a fast-spreading or high-intensity fire and to utilize natural or constructed firebreaks fuel breaks and favorable breaks in the topography. The intervening fuel is usually backfired; but occasionally the main fire is allowed to burn to the line, depending on conditions.


Indirect attack
Method of firefighting in which water is pumped onto materials above or near the fire so that the splash rains onto the fire, often used where a structure is unsafe to enter.


Infrared (IR) detector
A heat detection system used for fire detection, mapping, and hotspot identification.


Initial attack
First point of attack on a fire where hose lines or fuel separation are used to prevent further extension of the fire.


Initial attack
The actions taken by the first resources to arrive at a wildfire to protect lives and property, and prevent further extension of the fire.


Intake
Part of pump where water enters when pump forms partial vacuum.


Interface zone
Where urban firefighting meets wildland firefighting. Structures at the edges of wildlands are threatened and require skills and equipment of both disciplines.


Interface zone (also wildland/structural interface or urban/wildland interface)
The zone where wildfires threaten structures or structural fires threaten wildlands, such as in residential areas adjacent to forests. This requires both wildland firefighting and structural firefighting in the same location, which involve very different tactics and equipment.


Irons
The flathead axe mated with the halogon bar


Irons, or Set of irons
Pairing of a flat-head axe and a Halligan tool. A common combination used in forcible entry operations to gain access for search and rescue as well as interior fire attack.


ISO Rating
(Insurance Services Office Fire Insurance Rating) This is a rating published by the Insurance Services Office. Insurance companies use this number to determine homeowner insurance premiums.





Recent Calls

Sun. Aug 29th 2010
Reported House Fire

At 16:32 hrs. The Mahanoy City Fire Department along with Frackville Ladder 43-20 and Altmont RIT were dispatched to the 900 ...

Read more »


Sun. Aug 29th 2010
Engine And Squad On Rubbish Fire

At 03:07 hrs. Engine 454 was dispatched to the Borough garage on Park Place Rd. for a brush fire. Engine 454 arrived on scene...

Read more »


Sat. Aug 28th 2010
Tower Assist To Police

At 13:37 hrs. Tower 456 was requested to the 400 block of West Centre St. to assist police on locating a child on the roof. T...

Read more »

Upcoming Events

Every Mon. 7:00pm
Weekly Pick 5 Drawing


Every 1st Thu. 7:30pm
Company Meeting


Every 3rd Thu. 7:30pm
Company Meeting

Picture Gallery
Search Our Site

Search:



2010 Call Volume
  Fire EMS
January  7  71
February  6  54
March  7  62
April  5  50
May  6  65
June  17  83
July  14  50
August  11  68
September  1  11
October    
November    
December    
Total 74514

View Call Volume History

Visitor Poll

Are you a fire chaser?



Birthdays for September

23rd Christopher Andrusichen
26th Ronald Weller


YourFirstDue.com Managed web hosting for Fire/EMS

Advertisements





Login



Copyright © 2006-2010. YourFirstDue Inc.. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Content on this web site is supplied by Citizens Fire Company #2. YourFirstDue Inc. cannot be held responsible or liable for any content, text, pictures, or any other media found on this web site. Maintained by the members and staff of Citizens Fire Company #2.

This site has been
viewed 206,706 times.